300W 24V Wind Solar Hybrid Controller Standard Configuration Table
TYPMAR WIND SOLAR HYBRID CONTROLLER STANDARD CONFIGURATION TABLE
TM-WSC300-A01
Operational Parameters
Model No | TM-WSC300-1 |
Battery Rated Voltage | 24V |
Wind turbine Rated power | 300W |
Wind Turbine Maximum Charging Current | 12A |
Solar Panel Maximum Charging Current | 15A |
Solar Panel Maximum Open Circuit Voltage | 45V |
Battery overcharge protection Voltage | 28.6V |
Battery over discharge protection Voltage | 21V |
Battery overcharge recovery voltage | 24V |
Solar voltage at light control open | (2V)Adjustable |
Solar voltage at light control close | (3V)Adjustable |
Maximum Output Current | 10A |
LED Dimmer mode | Stepless dimming PWM intelligence |
Output Control mode (factory mode) | 1,normal open, 2,Light control : On/Off , 3,Light control: open, Timing control: off . |
Wind turbine unload control mode | PWM Soft brake |
Display and Setting Mode | Outlay LCD Screen and Buttons |
Working Temperature | -20~+55℃/35~85%RH (NO Dew formation) |
Standby current | 20±2 mA |
3,Standard configuration
TYPMAR WIND SOLAR HYBRID CONTROLLER STANDARD CONFIGURATION TABLE | |||
Made by : TYPMAR technology department | |||
No. | Item | Parameter | Remark |
1 | Battery rated voltage | 24 V | 24v lead-acid battery or gel battery is suitable |
2 | Wind turbine rated power | 300 W |
|
3 | Solar pv max voltage | 45 V | It may demage the controller if the voltage over 45v |
4 | Solar pv max current | 15A |
|
5 | Load max current | 10A |
|
6 | Intelligent dimming function | yes |
|
7 | The battery open circuit protection function | yes |
|
8 | Battery over discharge alarm voltage | 22V | If voltage lower than 22v , close output |
9 | The battery over discharge voltage recovery | 24 V | After over discharge protection start, must charge the battery make sure the voltage over than 24v , then system return to normal output |
10 | battery voltage over charge protection | 28.6 V | The battery voltage over 28.6v ,then stop charging |
11 | load over voltage protection | 32 V | Over the voltage, shut off the output |
12 | The RPM of wind turbine braking | 700 RPM |
|
13 | The typhoon judgement and protection | 4 times | Turbine RPM over 700 RPM, brake for 2 minutes. Inside half an hour, four times consecutive braking judge to typhoon,controller start the typhoon protection brake |
14 | After the typhoon , braking time | 1 hour |
|
15 | Wind turbine pole NO. | 8 pairs |
|